Ships within 8 hours (on average).
Ships within 8 hours (on average).
Free Shipping RM48 (2-3 days if ordered before 2pm) Upgrades available at checkout (e.g. tracked service and courier for time sensitive deliveries)
Call: 01242 522244 Email: sam@fixaball.co.uk Website: www.fixaball.co.uk for technical and sales queries
Fixaballsells all lengths of M10 Loose Hex Bolt, Heavy Duty Masonry Anchors.
Optimising your fixings holding capacity.
Orders placed before 2pm are dispatchedsame day (Mon-Fri).
Standard, is Royal Mail, 2nd Class (2-5 days, most likely 2 days). For a er delivery time, select 1st class or courier at checkout.
Please make your size and pack quantity selection from the drop down menus.
Important Loose Bolt Anchor Performance Dimensions
Thread Diameter of Hex Bolt | Shield Hole Size | Max Fix.Thickness |
M10 | 16mm | 10mm |
M10 | 16mm | 25mm |
M10 | 16mm | 50mm |
M10 | 16mm | 75mm |
NOTE: the1stdimension refers to the thread diameter and not the hole diameter. Please see the table below for further information on what masonry drill bit to use. The2nddimension refers to the maximum fixture thickness (space between the underside of the head and the shield +/- 5mm). The3rddimension is the actual length of the hex-bolt/ hex-set that goes into the sheild (in brackets).
Installation of Shield Anchors
When drilling holes you must respect the specified minimum depth and diameters shown in the table below. Holes must be square to the surface of the base material (e.g concrete) for safety during installation and to optimise holding capacity. Use the material/ fixture as a template to dill accurate locations.
If drilling through concrete that has rebar reinforcements, special care must be taken to avoid damaging them. If some rebar is encountered, abort the hole, repair with high quality mortar and create a hole, no less than twice the diameter of the shield anchor, away.
Table: Shows typical masonry shield values and measurements
All measurements in Metric - mm (all lengths are taken from under the hexagan head) |
||||||||
Thread Diameter |
Hole Diameter |
Hole Depth |
Fixture/ Material Clearance Hole |
Centre Spacing Between Holes |
Minimum Distance From Edge of Material |
Tensile/ Pull Load k/N (tonnes) |
Shear Load k/N (tonnes) |
Torque to tighten Nm |
M10 |
16 |
65 |
11 – 12 |
180 |
120 |
6.2 |
6.1 |
27 |
All specifications are true with correct installation |
Socket size guide:
M10 - 17mmSpanner
Image is for illustrative purposes only.
| Updated: 17th May 2025
All our sellers are verified
100% secure payment
Online Support